		DOB NOW: Build Updates - LAA DOB NOW: Build will be updated with a  number of changes specific to the Limited Alteration Application (LAA) work  type. In response to feedback  from industry members, the following changes are being implemented: Electronic Submission of Civil Penalty Waivers (L2)L2: Requests for Overrides, Reductions or Waivers of  Civil Penalties for Work Without a Permit for LAA jobs can no longer be  submitted using the DOB NOW help form. LAA filings created  on or after June 15 will complete the L2 form as part of the application. A scanned copy of the paper L2 form should not be uploaded.
 If a building has a Work Without  Permit violation, the LAA applicant will automatically receive a notification  upon clicking the File button. Applicants will be prompted to select Request L2 from the Filing  Action column on their DOB NOW dashboard. This will create a new tab on the LAA application where all the  information that had previously been provided on the L2 paper form will now be  entered. Depending on the L2 request code  selected, the system will automatically require upload of supporting documents. The LAA L2 can be requested and  submitted by LAA licensees as well as building owners if their information had  been entered on the LAA prior to clicking the File button. After DOB completes  the review of the L2, an email will be sent stating whether the L2 has been  approved and the LAA can be filed or the L2 has been rejected and a new L2 must  be submitted. Additional Changes  to DOB NOW: Build LAA job filingsThe changes described  below have been made to the LAA work type and primarily affect the Scope of  Work and Fee sections.  All changes are  applicable to new LAA job filings that are created on or after June 15 or were  still in Pre-Filing status on June 12.   Changes will also apply to PAAs that are in Pre-filing or Objections  statuses if the specific fields are editable on the PAA.
 
  
    | CATEGORY | DESCRIPTION |  
    | Asbestos Abatement ComplianceCAI and Control #
 | CAI and Control # will now only be required once per job filing. The system will no longer request the ACP 5 Certification Number and Asbestos Control Number for each appliance separately. |  
    | Category of Work Change  
        new installation of water meter | New installation of Water Meter (sub meter) must now be filed as Category 1. |  
    | Category of Work Change  
        rearrange/remove sprinkler    heads | Rearrange/remove sprinkler heads off the domestic will be added    to Category 1 item types and will now only be allowed to be filed in Category    1  |  
    | Addition of Item Type | A    new item type in the Water work type has been added to allow applicants to    perform work on a commercial sink. |  
    | Addition    of Item Type  | Added    option to select gas piping for all gas fueled appliances. |  
    | Addition    of Item Type  | Added option to select gas repair for gas    fired appliances when the work does not include any gas piping work. Gas    repair may include but is not limited to the following: 
        Gas    valvesGas    meter and meter barCouplings |  
    | Removal of Item Type 
        Emergency Eye WashEmergency Shower | New installations of the following plumbing fixtures will no longer be allowed to be filed on an LAA: 
        Emergency Eye WashEmergency Shower |  
    | Removal of Item Type | New installation of a primary water meter can no longer be filed on an LAA and must be filed as a PL (Plumbing) Work Type. |  
    | Appliance Data Grid  
        optional for certain item types  | The appliance data grid will not be required    when:selecting    ‘Gas Flex’ or ‘Gas Tankless Coil’;
 
        removing    any gas fired appliance;filing    for fire suppression work.  |  
    | Required    Document Change | Borough Office Approval Letter for an    additional meter will only be required in the following scenarios: 
        In residential buildings 1 or 2 family |  
    | Required    Document Change | Chimney Letter will automatically be required in the following cases:New installation of hot water heater:
 
        New installation of a Gas Hot Water Heater CAT 1 Vent (Atmospheric Vent Standard Chimney).New installation of a Gas Hot Water Heater CAT 2 Vent (Atmospheric Vent Lined Chimney). Replacement of Hot Water heater:  
        Applications for two or more hot water heaters and answers ‘no’ to “Do you have an existing job number?”  |  
    | Required Document Change | Question has been added to reduce when an electrical permit is required: 
        “Are you establishing permanently connected circuits or hard wire circuits?” If ‘no’, electrical permit is not required. |  
    | Required Document Change | When filing for a secondary backflow device, Form OP129 will no longer be required    ‘Prior to Permit’; it will now be required ‘Prior to Sign Off. |  
    | Filing    Fee for Oil Work | All LAAs with a scope of work for oil work will have a flat    filing fee of $130.  |  
    | Filing Fee for 1/2/3 Family  non-Residential
 | Minimum filing fee for 1/2/3 Family building type, where building use is Commercial,    Mixed Use, or Other will be $195 (with the exception of Oil Work that has a    minimum flat filing fee of $130). |  Visit the DOB  NOW: Build LAA Resources page for more information or submit an inquiry at www.nyc.gov/dobnowhelp. 
 
		
		More DOB NOW: Build Updates Please  note, these changes only affect existing DOB NOW work types, and no new work  types are being added in this release. 
  
    | WORK TYPE | CATEGORY | DESCRIPTION |  
    | MS Mechanical Systems  | Modify Subcategories of Mechanical Proposed Work  | Mechanical proposed work subcategories can be modified (Added or Deleted) when the filing is in any of the below    statuses:  
        CorrectionsIncompleteObjectionsQA Failed If the filing has been approved,    the subcategories can be modified through a Post Approval Amendment (PAA). To add a subcategory:First, on the PW1 tab, in the    Filing Review Type section, check additional Proposed Work subcategory:
 
        Heating SystemsVentilation SystemsAir Conditioning SystemsRefrigeration SystemsCooling TowersAssociated Ducts and PipingGeneratorsOthers Second, on the Scope of Work tab,    in the Equipment Specification Table, select +Add to include items in the added    subcategory. To delete a subcategory:First, on the Scope of Work tab, in the Equipment Specification    table, scroll to the right and click the Delete button for all items in the    subcategory. Second, on the PW1 tab, in the Filing Review Type section, uncheck    the proposed work subcategory.
 |  
    | FN, SF, SH Fence,Scaffold,
 Shed
 | Progress Inspection – Final | On jobs filed on or after June 15, 2020, an option to select who will perform the final progress inspection has been added to the PW1, Filing    Review Type section. Select Department of Buildings or Registered Design    Professional (Progress Inspection – Final will be added to the application). This option cannot be changed with a PAA.  |  
    | PW1 Applies to all work types that use the PW1  | Record Management Fee change | The Record Management Fee will be waived for Subsequent filings (a filing with a -S1, -S2, -S3… suffix). In addition, any Initial filing (-I1) that has an Associated New Building BIS Job Number will continue to have the Record Management Fee waived. |  
    | PW1 Applies to all work types that use the PW1 | Add/Remove Floors | Work on Floor under Location Information on the PW1 tab can be modified (Add or Delete) when the filing is any of the below statuses:  
        CorrectionsIncompleteObjectionsQA Failed If the filing is approved, Work on Floor can be modified through a post approval amendment (PAA). To modify the Work on Floors table, select +Add or scroll to the    right and select the Delete button under Actions. |  
    | PW1 Applies to all work types that use the PW1  | Work Types added to Application Highlights  | The work types included in a PW1 filing will be displayed in the Application Highlights section in the industry portal. It    will also display on the PDF when View Filing is selected. |  Visit the DOB NOW: Build Resources page for more information or submit an inquiry at www.nyc.gov/dobnowhelp. 
 |